A battery is easier to size when the question is specific: which appliances should keep running, and for how long? A list of selected circuits is more useful than a promise of whole-home backup. Use the local examples below as a starting worksheet, then replace every assumption with appliance or installer data.
kWh and kW answer different questions
Energy in kWh describes the amount stored. Power in kW describes how quickly energy is delivered. A larger battery does not automatically provide a higher AC output. Battery-side DC ratings, inverter AC output, starting demand and the backup-circuit arrangement must all support the intended loads.
A local load worksheet
Lights, fans & refrigeration · 300 W
- LED lighting: 40 W
- Two fans combined: 120 W
- Router: 20 W
- Refrigeration running allowance: 120 W
Home office circuit · 500 W
- Desktop computer: 200 W
- Monitor: 40 W
- Router: 20 W
- Lighting: 40 W
- Fan: 60 W
- Refrigeration allowance: 140 W
Extended home essentials · 800 W
- Refrigerator allowance: 140 W
- Two fans combined: 120 W
- Television: 100 W
- LED lighting: 60 W
- Router: 20 W
- Freezer allowance: 160 W
- Desktop computer: 200 W
An indicative runtime, with assumptions visible
For comparison only: runtime in hours = nominal battery energy × assumed usable fraction × assumed conversion efficiency ÷ average load in kW. The example uses 90% usable energy and 90% conversion efficiency as planning assumptions, not product guarantees. Actual runtime also depends on reserve settings, temperature, ageing, standby consumption, duty cycles and the selected inverter.
Illustrative TR6000WX-Pro example
| Assumed load (W) | Indicative runtime (h) |
|---|---|
| 300 | 27.6 |
| 500 | 16.6 |
| 800 | 10.4 |
10.24 kWh nominal energy; assumptions 0.90 × 0.90. This is a calculation, not a tested local household result.
Choose the architecture before the capacity
EU 230 V and TA6000 are integrated battery-and-inverter families. A second standalone inverter is not part of their basic product architecture. TR Pro, TR standard, HP Ultra, HP K and TB are batteries that need a compatible external inverter. Match voltage range, current limits, communication protocol and firmware; nominal voltage alone does not establish compatibility.
Use the backup explorer for a first comparison, then send the selected loads, required duration and existing inverter details with your enquiry. Electrical design and final compatibility need to be confirmed for the actual project.
Questions for your installer
Is a higher IP rating enough for a Thai rainy-season location?
No. Use the selected model's installation manual and the actual site's rain, splash and moisture exposure. The reviewed literature does not establish unrestricted outdoor, flood, condensation or salt-spray suitability from IP66 alone.
Can these backup examples include air conditioning?
The example circuits intentionally exclude air conditioning. Add your unit's actual running power, compressor starting requirement and target duration to a separate load plan, then confirm both the battery configuration and inverter capability.
Which site details make the quotation more useful?
Provide the region, proposed equipment area, observed temperature range and rain or damp exposure, plus the existing inverter model and essential circuits. Confirm the exact configuration, installation scope and availability with the supplier.