TB rack

Low-voltage battery

TB rack.

Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter.

INVERTER
Compatible external inverter required
ENCLOSURE
IP20
NOMINAL ENERGY
5.12–16.076 kWh
BATTERY VOLTAGE
51.2 V nominal DC
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated DC (kW)
TB4000X5.125
TB6000X10.2410
TB8000X14.33610
TB8500X16.07610

Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC.

ModelDimensions (mm)Approx. kg
TB4000X482 × 178 × 420 / W × H × D42
TB6000X482 × 223 × 550 / W × H × D78
TB8000X482 × 223 × 710 / W × H × D109.5
TB8500X482 × 223 × 710 / W × H × D112

Communication: RS485 / CAN / RS232
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

Choose for the room, the season and the region.

A hot enclosed room, a rain-exposed southern home and a northern cool-season location need different checks. Localize the installation plan around the battery's real environment, not a single label for Thailand.

Temperature:
Charge 0 to 55 °C; discharge −20 to 60 °C
ENCLOSURE
IP20
01

Central home · heat in the equipment room

An enclosed utility room can have different conditions from outdoor weather; assess the actual room.

An EU all-in-one needs a location consistent with its IP21 enclosure and model manual. Preserve ventilation and service access. Its listed charge 0 to 55 °C range is not a guarantee of full-power operation in a sun-heated or unventilated space.

Does the room collect roof or afternoon heat?
  • What temperature is observed at the battery position during use?
  • Can equipment clearances and ventilation stay unobstructed?
02

Southern home · monsoon exposure

Southern rainfall patterns differ from the north; the southeast can remain rainy under the northeast monsoon.

Plan a dry, sheltered equipment area and evaluate rain entry, coastal air and water exposure at the actual site. TR Pro and HP Ultra list IP66, but no salt-spray or flood guarantee is established by the reviewed product literature.

Can rain or splash reach the equipment area?
  • Is there coastal or salt-air exposure?
  • Which sheltered position is accessible for inspection and service?
03

Northern home · seasonal temperature change

The northeast monsoon brings cooler, drier conditions to much of northern and northeastern Thailand.

Record the actual low temperature and any damp or condensation exposure at the chosen location. Check the selected battery's charging limits; optional self-heating must be confirmed for the exact model rather than assumed to enable sub-zero charging.

What is the lowest temperature at the battery location?
  • Is damp or condensation seen during seasonal changes?
  • Which inverter voltage and communication interface does the system require?
Specifications
  • Keep the inverter relationship clear: an EU or TA6000 all-in-one includes an inverter; an HP, TR or TB battery-only installation requires a compatible external inverter.
  • Do not transfer climate limits across families. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C; HP Ultra's selected configuration temperature limits need confirmation.
  • Separate enclosure selection from climate assumptions. EU is IP21; TR standard and HP K list IP20 with optional IP54, TB is IP20, and TR Pro / HP Ultra list IP66. Confirm shelter, damp exposure and model-specific installation requirements.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos.

Original front terminal and control strip
Original front terminal and control stripFront terminal and control strip, with the negative terminal left and positive terminal right.
Negative power terminal, front left
Negative power terminal, front leftNegative terminal and minus mark at the front left.
Positive power terminal, front right
Positive power terminal, front rightPositive terminal and plus mark at the front right.
Original communication and control area
Original communication and control areaCommunication connectors, indicators and power switch on the front control strip.
Original cell and BMS construction detail
Original cell and BMS construction detailPartial internal illustration showing battery cells and the BMS board.

Know your interfaces.

Power connections

Positive power terminal
Power port on the viewer's right in the illustrated front panel, with the original plus mark.
Negative power terminal
Power port on the viewer's left in the illustrated front panel, with the original minus mark.

Communication

Dry Connect (source label)
Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given.
COM0 / COM1 parallel ports
Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied.
CAN / RS485
Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol.
RS232
Communication port named RS232; exact pinout and adapter requirements are not provided.

Controls & indicators

Power switch
Power on/off switch as described in the original caption. Operating sequence is not supplied.
SOC / ALM / RUN indicators
Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified.
Address identification control
Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified.

Structure & mounting

Laser welding
The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port.
Steel holder
Internal steel holder identified as fixing the cells; not an external connector.
Plastic steel belt (source wording)
Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated.
Built-in smart BMS
Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions.
Portable handle
Steel handle as described in the source. It is not an electrical port.

Source: Residential ESS brochure · PDF page 7 · printed pages 13-14