EU 230 V

Integrated system

EU 230 V.

An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW.

INVERTER
Included
ENCLOSURE
IP21
NOMINAL ENERGY
10.24 / 16.076 kWh
AC CONFIGURATION
230 V AC / 50 or 60 Hz
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated AC (kW)
6.2K-10/16KWH-EU10.246.2
6.2K-10/16KWH-EU16.0766.2
12K-16KWH-EU16.07612

6.2 kW AC configurations: 1 MPPT and max. PV 6.5 kW. 12 kW AC: 2 MPPT and max. PV 2 × 9 kW. Wi-Fi, parallel operation and CT options require confirmation.

ModelDimensions (mm)Approx. kg
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H105
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H130
12K-16KWH-EU552 × 254 × 1210 / L × W × H130

Communication: USB / RS485 / dry contact
Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C

Choose for the room, the season and the region.

A hot enclosed room, a rain-exposed southern home and a northern cool-season location need different checks. Localize the installation plan around the battery's real environment, not a single label for Thailand.

Temperature:
Charge 0 to 55 °C; discharge −20 to 55 °C
ENCLOSURE
IP21
01

Central home · heat in the equipment room

An enclosed utility room can have different conditions from outdoor weather; assess the actual room.

An EU all-in-one needs a location consistent with its IP21 enclosure and model manual. Preserve ventilation and service access. Its listed charge 0 to 55 °C range is not a guarantee of full-power operation in a sun-heated or unventilated space.

Does the room collect roof or afternoon heat?
  • What temperature is observed at the battery position during use?
  • Can equipment clearances and ventilation stay unobstructed?
02

Southern home · monsoon exposure

Southern rainfall patterns differ from the north; the southeast can remain rainy under the northeast monsoon.

Plan a dry, sheltered equipment area and evaluate rain entry, coastal air and water exposure at the actual site. TR Pro and HP Ultra list IP66, but no salt-spray or flood guarantee is established by the reviewed product literature.

Can rain or splash reach the equipment area?
  • Is there coastal or salt-air exposure?
  • Which sheltered position is accessible for inspection and service?
03

Northern home · seasonal temperature change

The northeast monsoon brings cooler, drier conditions to much of northern and northeastern Thailand.

Record the actual low temperature and any damp or condensation exposure at the chosen location. Check the selected battery's charging limits; optional self-heating must be confirmed for the exact model rather than assumed to enable sub-zero charging.

What is the lowest temperature at the battery location?
  • Is damp or condensation seen during seasonal changes?
  • Which inverter voltage and communication interface does the system require?
Specifications
  • Keep the inverter relationship clear: an EU or TA6000 all-in-one includes an inverter; an HP, TR or TB battery-only installation requires a compatible external inverter.
  • Do not transfer climate limits across families. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C; HP Ultra's selected configuration temperature limits need confirmation.
  • Separate enclosure selection from climate assumptions. EU is IP21; TR standard and HP K list IP20 with optional IP54, TB is IP20, and TR Pro / HP Ultra list IP66. Confirm shelter, damp exposure and model-specific installation requirements.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

Views and numbering come only from the supplied one-page EU brochure. The source does not provide pinouts, cable sizing, wiring procedures or a complete set of every exterior face. Native side-image resolution is modest. A rendered map improves the original vector labels, not the native photographic detail.

Original numbered interface map
Original numbered interface mapNumbered map of the AC, battery, PV and communication connections.
AC and battery connection side
AC and battery connection sideAC and battery connection side with cooling fans and the battery breaker.
AC and battery upper detail
AC and battery upper detailUpper AC connection area, cooling fans and BAT terminals.
PV and communication side
PV and communication sidePV and communication side, including the battery communication ports.
PV and communication upper detail
PV and communication upper detailVentilation grille above the PV and communication connection area.

Know your interfaces.

Power connections

AC input / output
The AC connection identified by number 1 in the original map.
AC input breaker
Breaker labelled for the AC input.
BAT+ / BAT-
Positive and negative battery terminals, as labelled in the source.
PV input
Input identified for the PV connection.

Communication

Parallel communication port
Communication connection labelled for parallel operation; configuration availability must be confirmed separately.
Dry contact control
Control interface labelled as dry contact in the brochure.
RS485 / BMS communication port
The communication connection named RS485/BMS in the original label.
Wi-Fi port
Port labelled Wi-Fi; the source specification lists Wi-Fi as an option requiring confirmation.
USB communication port
Communication interface labelled USB.
Battery communication ports
The source points to the group of three circular openings with label 11. It does not identify these as AC power inputs.

Controls & indicators

Battery breaker
Breaker identified for the battery section.

Source: EU 230 V product sheet · PDF page 1