# TA6000.

![TA6000](https://th.elvorka.com/assets/optimized/3767e02b99d59eea-1254-q92.webp)

Integrated system

# TA6000.

Battery and inverter in one cabinet, with PV input connectivity and three specified storage configurations. AC output options depend on the selected configuration.

INVERTER  Included

ENCLOSURE  Not specified

NOMINAL ENERGY  10.24–20.48 kWh

AC CONFIGURATION  120 V US / 230 V EU AC options

[Start your project ↗](https://th.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | AC options (kW) |
| --- | --- | --- |
| TA6000-M2 | 10.24 | 6–10 |
| TA6000-M3 | 15.36 | 6–12 |
| TA6000-M4 | 20.48 | 6–12 |

Specify the correct market AC voltage and 50 / 60 Hz option. PV input: 11 kW for M2; 11–13.2 kW for M3/M4. No three-phase or split-phase capability is claimed.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TA6000-M2 | 590 × 570 × 1880 / W × D × H | 244 |
| TA6000-M3 | 590 × 570 × 1880 / W × D × H | 286 |
| TA6000-M4 | 590 × 570 × 1880 / W × D × H | 328 |

Communication: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional
Temperature: Operating −20 to 60 °C

## Choose for the room, the season and the region.

A hot enclosed room, a rain-exposed southern home and a northern cool-season location need different checks. Localize the installation plan around the battery's real environment, not a single label for Thailand.

Temperature:  Operating −20 to 60 °C

ENCLOSURE  Not specified

01

### Central home · heat in the equipment room

An enclosed utility room can have different conditions from outdoor weather; assess the actual room.

An EU all-in-one needs a location consistent with its IP21 enclosure and model manual. Preserve ventilation and service access. Its listed charge 0 to 55 °C range is not a guarantee of full-power operation in a sun-heated or unventilated space.

Does the room collect roof or afternoon heat?

- What temperature is observed at the battery position during use?

- Can equipment clearances and ventilation stay unobstructed?

02

### Southern home · monsoon exposure

Southern rainfall patterns differ from the north; the southeast can remain rainy under the northeast monsoon.

Plan a dry, sheltered equipment area and evaluate rain entry, coastal air and water exposure at the actual site. TR Pro and HP Ultra list IP66, but no salt-spray or flood guarantee is established by the reviewed product literature.

Can rain or splash reach the equipment area?

- Is there coastal or salt-air exposure?

- Which sheltered position is accessible for inspection and service?

03

### Northern home · seasonal temperature change

The northeast monsoon brings cooler, drier conditions to much of northern and northeastern Thailand.

Record the actual low temperature and any damp or condensation exposure at the chosen location. Check the selected battery's charging limits; optional self-heating must be confirmed for the exact model rather than assumed to enable sub-zero charging.

What is the lowest temperature at the battery location?

- Is damp or condensation seen during seasonal changes?

- Which inverter voltage and communication interface does the system require?

Specifications

- Keep the inverter relationship clear: an EU or TA6000 all-in-one includes an inverter; an HP, TR or TB battery-only installation requires a compatible external inverter.

- Do not transfer climate limits across families. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C; HP Ultra's selected configuration temperature limits need confirmation.

- Separate enclosure selection from climate assumptions. EU is IP21; TR standard and HP K list IP20 with optional IP54, TB is IP20, and TR Pro / HP Ultra list IP66. Confirm shelter, damp exposure and model-specific installation requirements.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

The supplied brochure provides two labelled connection/breaker insets and internal cabinet/cell illustrations on printed pages 15-16. Crops avoid visible product logos without AI editing, repainting, or invented structure. Embedded views not visibly matched to the printed product page were excluded. These views do not establish pinouts, cable sizes, commissioning steps or installation compatibility.

[![Original terminal labels](https://th.elvorka.com/assets/product-details/ta-terminal-map.png)](https://th.elvorka.com/assets/product-details/ta-terminal-map.png)

Original terminal labels  Connection panel labelled for load, grid, optional generator, PV and communication.

[![Terminal panel close-up](https://th.elvorka.com/assets/product-details/ta-terminal-closeup.png)](https://th.elvorka.com/assets/product-details/ta-terminal-closeup.png)

Terminal panel close-up  Close-up of the cabinet terminal panel.

[![Original breaker labels](https://th.elvorka.com/assets/product-details/ta-breaker-map.png)](https://th.elvorka.com/assets/product-details/ta-breaker-map.png)

Original breaker labels  Battery, PV1, PV2, load and grid breakers in the illustrated compartment.

[![Breaker compartment close-up](https://th.elvorka.com/assets/product-details/ta-breaker-closeup.png)](https://th.elvorka.com/assets/product-details/ta-breaker-closeup.png)

Breaker compartment close-up  Circuit breakers within the cabinet's breaker compartment.

[![Upper cabinet and service bay](https://th.elvorka.com/assets/product-details/ta-service-bay.png)](https://th.elvorka.com/assets/product-details/ta-service-bay.png)

Upper cabinet and service bay  Upper cabinet compartment with the inverter and connection area.

[![Cell assembly detail](https://th.elvorka.com/assets/product-details/ta-cell-assembly.png)](https://th.elvorka.com/assets/product-details/ta-cell-assembly.png)

Cell assembly detail  Battery cell tops in a partial internal illustration.

### Know your interfaces.

#### Power connections

Load Output  Output position identified as Load Output in the brochure.

Grid Input  Connection position identified as Grid Input.

Generator Input (optional)  The generator input is explicitly marked optional in the original callout.

PV Input  PV connection area identified by the original callout.

PV1 Input Breaker  Breaker identified for PV1 Input.

PV2 Input Breaker  Breaker identified for PV2 Input.

#### Communication

Communication Port  Connection area labelled Communication Port. No protocol pin assignments are specified in this component view.

#### Controls & indicators

Battery Breaker  Breaker labelled for the battery section.

Load Breaker  Breaker identified for the load connection.

Grid Breaker  Breaker identified for the grid connection.

Source: Residential ESS brochure · PDF page 8 · printed pages 15-16

---

https://th.elvorka.com/en/products/ta6000/